R60 Series
Programmable, DPDT, 10 Amp, AC or DC, Delay on Operate Time Delay Relay
|
Features
16 Time Ranges in a Single Timer
User Sets Time Ranges (No Math - Just Flip Switches
Instructions right on Unit
Fine Tune Knob for Precision Timing
Pin for Pin Interchangable with Timers in the Field - No Rewiring
AC or DC Operation
CMOS Digital Circuitry - 0.5% Repeatable Accuracy
|
DELAY ON OPERATE - The delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied.
Electrical Characteristics
Contact
Contact Rating: 10 Amps 240VAC or less, 1/3 HP, 240VAC or 120VAC,
Pilot Duty 345VA, 120VAC or 240VAC, 50/60Hz
Life: 500,000 operations at full load
Mechanical Life: 7,000,000 operations at no load
Input
Nominal Input Voltages: See Chart
Steady State Input Current: See Chart
Timing
Timing Adjustment Modes Available: See Timing Range Chart
Repeat Accuracy
±0.5% - after established at steady temperature (4 hours)
Timing Tolerance at High End of Range: -0, +10%
Timing Tolerance at Low End of Range: +0, -50%
Reset Time: 60mS Typ
Protection
Transient: Surge Test 10,000V for 20mS
Dielectric Breakdown:
Coil To Contact: 1850 VAC
Across Open Contact: 1850 VAC
Environmental Characteristics
Operating: -20°C to +55°C
Weight
Std: 4.5 ozs. (130 grams) - approx
Back to Top
Dimensional Drawings
D35 Timing Range Chart
Contact Arrangment
DPDT, 2 Form "C" |
Timing |
Back to Top
Part Numbers
AC or DC OPERATED |
NTE Type No. |
Nom. Volt. |
Contact Arr. |
Input Cur. Nom. |
Max. Contact Cur,
@ 28VDC or 120VAC |
Diag. No. |
R60-11AD10-12 |
12VAC/DC |
DPDT |
167mA |
10A |
D35 |
R60-11AD10-24 |
24VAC/DC |
DPDT |
83mA |
10A |
D35 |
R60-11AD10-120 |
120VAC/DC |
DPDT |
17mA |
10A |
D35 |
ACCESSORIES |
Mounting Styles |
Description |
NTE Type No. |
Surface Mount |
8-Pin Octal |
R95-101 |
Panel Mount |
8-Pin Octal |
R95-118 |
DIN Rail
Mount |
8-Pin Octal |
R95-113 |
8-Pin Octal |
R95-181 |
Back to Top
|