 Product Links 
|
|

Inside SRI

|
SRI-Newsletter |
 |
Subscribe to our newsletter to receive monthly specials, manufacturer's feature, and electronics news via email. |
|
|
|
See Our latest release of SRI-Newsletter here
|
|
View Our List of Archived Newsletter Articles
|
|

SRI Links

|
|
Visit our Sister Site,
 Distributor of Industrial Products
| |
|
Web Search .. Powered by;
|
|
 |
 |
|
 |
 |
[ Arc Flash Protection ] [ Code Compliance ] [ Cost Savings ] [ Durability ] [ Quick Equipment Change-outs ] [ Superior Safety ]
Code Compliance
NEC
|
The NEC requires motors to have readily accessible “line of
sight” disconnects that are either an approved switch or a properly
rated plug and receptacle.
With their unique ability to
withstand high in-rush currents, Meltric Decontactor™ Series plugs
and receptacles are the perfect choice for the line of sight
disconnect required on motors and other inductive loads. DS, DSN and
DB Decontactors are horsepower rated and pass testing at the 6xFLA
current level required relative to locked rotor
conditions. |
|
 |
NFPA 70E
|
NFPA 70E requires that any person working near live parts
must wear protective clothing and equipment based on the calculated
incident energy exposure level or alternatively on NFPA’s listed
minimum requirements.
Once installed, Meltric
Decontactor Series plugs and receptacles simplify compliance to NFPA
70E requirements. Their dead
front construction eliminates the possibility of access to live
parts so there is no need to don personal protective equipment when
changing out motor or other equipment connected with Meltric
Decontactors.
Visit the NFPA website to read more about NFPA
70E |
|
 |
UL/CSA Listings
|
Meltric Decontactors are the world's only UL and CSA switch
rated plugs and receptacles. Not only do they meet performance test
requirements for UL 1682/CSA C22.2 No.182.1 (to which competitive
pin and sleeve devices are listed), but Decontactors also meet
performance test requirements for products listed to UL Subject 2682
"Switch-Rated Plugs and Receptacles", as well as, CSA C22.2 No.4
"Enclosed and Dead Front Switches" and CSA C22.2 No.14 "Industrial
Control Equipment." They are approved by UL and CSA for use in motor
circuit disconnect/switching applications and in branch circuit
disconnect/switching applications.
•
50 operations @ 6x motor FLA .4-.5
power factor
•
6000 operations @ FLA .75-.8 power
factor
• 4000
mechanical operations (10,000 total
operations)
•
Short circuit make and withstand @ 65kA, 600V and .4-.5 power
factor
Additional Listings include: IEC/EN 60309-1,
60947-3, AS 3123 |
|
**Specifications subject to changes**
[Go to Search] [Back]
|
|
|
|